1
/
of
5
PowerShield
PowerShield Centurion 1000VA uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA 900 W 4 AC outlet(s)
Regular price
$1,068.00 AUD
Regular price
Sale price
$1,068.00 AUD
Unit price
/
per
Use the contact form below to check availability.
1000VA, 900 W, 4 Outlets, 3 Batteries, 12 V, 9 Ah, 397 × 145 × 220 mm, 12500 g
Use Power Shield Centurion to protect:
Servers
Critical power applications
Items in remote areas (over 30 kms outside of city grid)
Where light to heavy industrial equipment is utilised
Where generators are present
Applications that require remote connectivity
PowerShield Centurion 1000VA quantity
Key Features
- True Online Double Conversion
- Wide input voltage range
- Input power factor correction 0.98
- 50Hz/60Hz frequency converter mode
- Programmable power outlets
- Emergency power off function (EPO)
- Optional Eco-mode operation for energy saving
- Generator compatible
- Backup time for all models is easily extended by simply plugging additional battery banks
- Battery banks are available with internal charger to enable fast recharge even with large battery banks
- USB, RS232, SNMP and AS400 multiple communications available
Description
The PowerShield Centurion UPS provides a permanent backup power solution for sensitive devices such as medical equipment and internet routers.Use Power Shield Centurion to protect:
Servers
Critical power applications
Items in remote areas (over 30 kms outside of city grid)
Where light to heavy industrial equipment is utilised
Where generators are present
Applications that require remote connectivity
PowerShield Centurion 1000VA quantity
Specifications
Power | |
---|---|
Output frequency | 57/63 Hz |
Output power capacity | 1 kVA |
Output power | 900 W |
Input operation voltage (min) | 160 V |
Input operation voltage (max) | 300 V |
Output operation voltage (min) | 200 V |
Output operation voltage (max) | 240 V |
Surge energy rating | 1248 J |
Efficiency | 90% |
Emergency Power Off (EPO) | Yes |
Power factor | 0.9 |
Output voltage regulation | 1% |
Input power factor | 0.99 |
Charging current | 1.5 A |
Efficiency (ECO mode) | 98% |
ECO mode | Yes |
Input frequency | 40 - 70 Hz |
Performance | |
UPS topology | Double-conversion (Online) |
Number of output phases | 1 |
Number of input phases | 1 |
Response time | 4 ms |
Waveform | Pure sine |
Noise level | 50 dB |
Features | |
Output frequency | 57/63 Hz |
UPS topology | Double-conversion (Online) |
Output power capacity | 1 kVA |
Number of output phases | 1 |
Number of input phases | 1 |
Response time | 4 ms |
Output power | 900 W |
Input operation voltage (min) | 160 V |
Input operation voltage (max) | 300 V |
Output operation voltage (min) | 200 V |
Output operation voltage (max) | 240 V |
Surge energy rating | 1248 J |
Efficiency | 90% |
Emergency Power Off (EPO) | Yes |
Waveform | Pure sine |
Power factor | 0.9 |
Output voltage regulation | 1% |
Input power factor | 0.99 |
Noise level | 50 dB |
Efficiency (ECO mode) | 98% |
ECO mode | Yes |
Input frequency | 40 - 70 Hz |
Power source type | AC |
Charging current | 1.5 A |
Ports & interfaces | |
Emergency Power Off (EPO) connector | Yes |
USB port | Yes |
AC outlets quantity | 4 AC outlet(s) |
AC outlet types | C13 coupler |
RS-232 ports | 1 |
USB port type | USB Type-B |
Battery | |
Number of batteries supported | 3 |
Battery recharge time | 4 h |
Battery voltage | 12 V |
Battery capacity | 9 Ah |
Charging current | 1.5 A |
Design | |
Form factor | Tower |
Product colour | Black |
Certification | EN62040 - 1 - 1 2003, IEC60950 - 1 - 1, EN62040 - 2 2006, Directive 2001 / 65 / EU |
Cooling type | Active |
Built-in fan | Yes |
Control type | Buttons |
Display type | LCD |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 20 - 95% |
Technical details | |
Output frequency | 57/63 Hz |
Compliance certificates | RoHS |
Cooling | |
Cooling type | Active |
Built-in fan | Yes |
Weight & dimensions | |
Width | 145 mm |
Depth | 397 mm |
Height | 220 mm |
Weight | 12.5 kg |
Certificates | |
Certification | EN62040 - 1 - 1 2003, IEC60950 - 1 - 1, EN62040 - 2 2006, Directive 2001 / 65 / EU |